Device Setup
This chapter describes the setup for the P630-2 under the following sections:
Device Location
The following are guidelines used to select an ideal location for the terminal.
Ease of Use
Select a location convenient for both merchant and cardholder.
Select a flat support surface, such as a countertop or table, or mount it on a mounting stand supplied by Verifone.
Select a location near a power outlet, POS, ECR, or computer connected to the terminal. Do not string cables or cords across a walkway for safety.
Periodic Inspection
Periodically inspect the terminal for possible tampering. Signs of tampering may include:
Wires that are protruding from the device.
Foreign objects inserted into the smart card or mag stripe slot.
Signs of damage to the tamper-evident label.
Warning message on the device display.
Environmental Factors
Do not use the unit where there is high heat, dust, humidity, moisture, caustic chemicals, or oils.
Keep the unit away from direct sunlight and anything that radiates heat, such as a stove or a motor.
Do not use the terminal outdoors.
The terminal is not waterproof or dustproof. It is intended for indoor use only. Any damage to the unit from exposure to rain or dust can void any warranty.
Le terminal n'est ni étanche ni étanche à la poussière. Il est destiné à un usage intérieur uniquement. Tout dommage causé à l'appareil par une exposition à la pluie ou à la poussière peut annuler toute garantie.
Electrical Considerations
Avoid using this product during electrical storms.
Avoid locations near electrical appliances or other devices that cause excessive voltage fluctuations or emit electrical noise (for example, air conditioners, electric motors, neon signs, high-frequency or magnetic security devices, or computer equipment).
Do not use the terminal near water or in moist conditions.
Disconnect the device from its POS terminal before cleaning.
Do not use the terminal near water, including a bathtub, washbowl, kitchen sink, or laundry tub in a wet basement, or near a swimming pool to avoid shock or damage.
N'utilisez pas le terminal à proximité de l'eau, y compris d'une baignoire, d'un lavabo, d'un évier de cuisine ou d'une cuve à lessive, dans un sous-sol humide ou à proximité d'une piscine pour éviter les chocs ou les dommages.
Contactless Considerations
Avoid having metallic objects in the proximity of a contactless antenna. If you need to mount the terminal to vertical or inclined surfaces, use a flat, non-metallic mounting plate.
Using an enclosed metal frame or mount may negatively affect contactless performance.
L'utilisation d'un cadre ou d'un support métallique fermé peut affecter négativement les performances sans contact.
PIN Protection Measures
Use the following techniques to provide effective screening of PIN-Entry Devices (PEDs) during the PIN-entry process. You can use these methods in combination, although in some cases a single method might suffice.
Position the terminal on the check-in stand in such a way as to block visual observation of the PIN-entry process. Examples include:
Visual shields designed on the check-in stand. The shields may be solely for shielding purposes or may be part of the general check-in stand design.
Position the terminal so that it is angled in such a way that PIN spying is difficult.
Install the PED on an adjustable stand that allows consumers to swivel the terminal sideways and/or tilt it forward/backward to a position that makes visual observation of the PIN-entry process difficult.
Position in-store security cameras so that the PIN-entry keypad is not visible.
In an attended handheld (or handover) mode, the users can pivot their bodies around to shield the device and block it from any prying eyes.
The following table describes the two preferred mounting methods and the recommended measures to protect against PIN capture in four observation corridors:
Countertop without stand
Use signage behind the PED
Install so that the customer is between PED and next in the queue
No action needed
Do not install within view of cameras
Countertop with stand
No action needed
Install so that the customer is between PED and next in the queue
No action needed
Do not install within view of cameras
Verifone also recommends instructions to the cardholder regarding safe PIN-entry. This can be done with a combination of:
Signage on the PED.
Prompts on the display, possibly with a click-through screen.
Literature at the point of sale.
A logo for a safe PIN-entry process.
User Privacy
Use the following guidelines to protect the user's privacy when he enters his Personal Identification Number (PIN):
The area of visibility should not be larger than a cone taken from the number 5 key at an angle of 45° and covering an area of 270° directly in front of the user.
Inside the Shipping Carton
Open the shipping carton and carefully inspect its contents for possible tampering or shipping damage. The terminal is a secure product. Tampering causes it to cease to function or to operate in an unsecured manner.
Remove and Inspect the Contents
Remove and inspect the contents of the shipping carton. The terminal ships in multiple configurations. The carton may include all or any of the following:
Device
Connectivity cable
This device is a secure product, and any tampering can cause it to cease to function or operate in an unsecured manner.
Cet appareil est un produit sécurisé et toute altération peut entraîner son arrêt de fonctionnement ou son fonctionnement non sécurisé.
SAM/TF Cards
To install or replace the SAM/TF card:

Installing or Changing SAM/TF Card
To install or change the SAM/TF card:
Observe standard precautions in handling electrostatically sensitive devices. Electrostatic discharges can damage the equipment. Verifone recommends using a grounded anti-static wrist strap.
Observez les précautions standard lors de la manipulation d'appareils sensibles aux décharges électrostatiques. Les décharges électrostatiques peuvent endommager l'équipement. Verifone recommande d'utiliser un bracelet antistatique mis à la terre.
Power Supply
Not all configurations and device contexts require the use of a power supply. Verifone ships the power supply with the terminal as required.
Contact your Verifone representative if you have changed the context in which the terminal is used or have questions about which power supply should be used.
Using an incorrectly rated power supply can damage the unit or cause it not to work properly. Use only a power pack with VPN PWR435-101- * - A (see Service and Support for detailed power supply specifications).
L'utilisation d'une alimentation électrique mal évaluée peut endommager l'appareil ou l'empêcher de fonctionner correctement. Utilisez uniquement un bloc d'alimentation avec VPN PWR435-101-*-A (voir Service et assistance pour les spécifications détaillées de l'alimentation).
Disconnect the power pack cord from the power outlet before connecting a power supply. Connect and route all cables between the terminal, ECR, and PC before plugging the power pack cord into a wall outlet or surge protector.
Do not plug the power pack into an outdoor outlet or operate the terminal outdoors. Disconnecting power during a transaction can cause transaction data files not yet stored in memory to be lost.
Ne branchez pas le bloc d'alimentation sur une prise extérieure et n'utilisez pas le terminal à l'extérieur. La déconnexion de l'alimentation pendant une transaction peut entraîner la perte des fichiers de données de transaction non encore stockés en mémoire.
When the terminal has power and an application is loaded, the application starts after the initial Verifone copyright screen and displays a unique copyright screen. If no application is loaded, DOWNLOAD NEEDED appears on the display after the initial Verifone copyright screen.
Manual Shutdown
Press the power button on the left side for at least 8 seconds, until the device display turns off, to power off the P630-2 device.

Cable Connections
The P630-2 has several cabling scenarios, depending on what it connects to:
Connecting to Another Verifone Terminal.
RS-232 Connection Using an External Power Brick.
Ethernet Connection with External Power Brick.
Turn off or unplug the terminal when connecting or disconnecting the device to avoid device memory corruption and data loss. Refer to the controlling device instructions for any terminal-specific warnings.
Éteignez ou débranchez le terminal lors de la connexion ou de la déconnexion de l'appareil pour éviter la corruption de la mémoire de l'appareil et la perte de données. Reportez-vous aux instructions du dispositif de contrôle pour tout avertissement spécifique au terminal.
Attaching a Cable Connector to the P630-2
The cables first have to be attached to the P630-2. To attach a cable to the terminal, follow the steps below:

Connecting to Another Verifone Terminal
The P630-2 can be powered by another Verifone terminal by Serial Connection.
Serial Connection
Configuration 1 - P630-2 to V200c
The P630-2 device is powered by the Countertop terminal via USB where the output power of the V200c. Connect the 28-pin connector of the coiled serial cable (Connected to the MOD 10 port, cable VPN - CBL435-002-01-A) to the P630-2, then insert the other end of the cable to the multi-communication port of the V200c.
Configuration 2 - P630-2 Full Feature
The PINpad accessories on the opposite side are used to connect the PC and the Electronic Cash Register (ECR).

RS-232 Connection Using an External Power Brick
A special dongle cable is used, where one end of the cable plugs into the P630-2 while the other end terminates into the DB-9 connector housing. On the housing, a DC jack is provided to connect to an external power brick. This is a generic cable for all RS232-based hosts (VPN - CBL282-031-XX-A).

Ethernet Connection with External Power Brick
To connect the terminal to other devices via Ethernet, use the cable with a junction box that provides a standard RJ-45 LAN socket, a mini-USB port, and a standard DC jack for an external power connection.
The junction box comes in these configurations:
Countertop without stand
Junction box with RJ-45 socket (for connecting the device to LAN infrastructure), MOD-8 socket for RS232 & DC-in jack
CBL282-006-01-B
Ethernet with RS232 and Mini-USB option
Junction box with RJ-45 socket (for connecting the device to LAN infrastructure), MOD-8 socket for RS232, Mini USB & DC-in jack
CBL435-005-02-A
Ethernet with RS232 and USB option
Junction box with RJ-45 socket (for connecting the device to LAN infrastructure), MOD-8 socket for RS232, Mini USB, type A USB & DC-in jack
CBL435-044-01-A
The figure below shows the connections available on the external power brick.

Smart Card Reader
The smart card transaction procedure can vary depending on the application. Verify the proper procedure with your application provider before performing a smart card transaction.

Conducting a Smart Card Transaction
To conduct a smart card transaction:
Leave the smart card in the card reader until the transaction is completed. Premature removal can void the transaction.
Laissez la carte à puce dans le lecteur de carte jusqu'à ce que la transaction soit terminée. Une suppression prématurée peut annuler la transaction.
Magnetic Stripe Card Reader
The P630-2 has a magnetic card reader that uses a triple-track stripe reader. This gives the unit greater reliability over a wide range of swipe speeds and operating environments.

Conducting a Credit/Debit Card Transaction
To conduct a credit or debit card transaction:
Contactless Transactions
The P630-2 supports contactless transactions through an integrated contactless module. The terminal only becomes active for contactless smart card transactions when initialized by an application.

Performing Contactless Transactions
To perform a contactless smart card transaction:
Optional Accessories
These accessories can be used to further enhance the device's functionality. See Accessories for additional information.
Privacy Shield
The privacy shield is used to hide the keys when the user is entering a password in a transaction. One type of privacy shield can be used:
Standard Type - This privacy shield is PCI-compliant. This must be used when P630-2 is not mounted on a swivel stand. The standard type privacy shield may be optionally used in attended handheld (or handover) mode, or when the P630-2 is mounted on a swivel stand (as for a multilane environment), or when the P630-2 is integrated into a kiosk and the kiosk has its own privacy shielding.

Installing the Privacy Shield
To install a privacy shield:
Mounting Plate
This accessory is used to mount P630-2 to vertical or inclined surfaces.
Attaching a Mounting Plate to P630-2
To attach a mounting plate to P630-2:
Mounting P630-2 with Mounting Plate to a Wall or Flat Surface
To mount the terminal to a wall or flat surface:
Mounting P630-2 to a Flat Surface (Without a Mounting Plate)
To mount the terminal to a flat surface:
Mounting P630-2 with Mounting Plate to a Vertical Bracket
To mount the terminal with a mounting plate to a vertical bracket:
Mounting Considerations
Avoid having metallic objects in proximity to the contactless antenna. If you need to mount the terminal to vertical or inclined surfaces, use a flat mounting plate.
External Camera
To mount the external semi-integrated camera for QR, Barcode, and OCR scanning:
An enclosed metal frame or mount may negatively affect CTLS performance.
Un cadre ou un support métallique fermé peut affecter négativement les performances du CTLS.

Last updated