For the complete documentation index, see llms.txt. This page is also available as Markdown.

Device Setup

Selecting Unit Location

Use the following guidelines when selecting a location for the UX115 device:

  • Select a location convenient for the customer.

  • Avoid dusty, hot or damp locations.

Environmental Factors

The UX115 is sealed to IP65 rating when mounted correctly in an enclosure.

Unpacking the Shipping Carton

Open the shipping carton and carefully inspect its contents for possible tampering or shipping damage.

  1. Validate the authenticity of the sender by verifying the shipping tracking number and other information located on the product order paperwork.

  2. Remove the items from the shipping carton. The standard package contains:

    • The UX115 unit

    • Grounding strap

    • USB cable

Figure 1: UX115 Device
  1. Remove any protective wrap before mounting the unit.

  2. Save the shipping carton and packing material for future repacking or moving of the device.

UX115 Connection Ports

The UX115 features the following ports:

Figure 2: UX115 Connection Ports
  • USB device (Type B) [client]

  • 2x Powered USB (Type A) Ports

    • 1 x Full Speed, High Powered USB (Type A), Port 1 [Host]

    • 1 x Powered USB (Type A), Port 2 [OTG]

  • Power port 12V DC to 24V DC

  • LAN

  • COM1 (RS-232)

Mounting the UX115

This section shows how to attach the UX115 device to the installation panel for stability and security.

Use the following steps to install the UX115 device:

Figure 3: Mounting the UX115 device
  1. Align the UX115 device mounting holes to the installation panel holes.

  2. Insert four bolts and tighten the nuts using a recommended tightening torque of 5.0 kgf cm (0.49 Nm or 4.3 lbf in).

Connecting UX115 to a Controlling Device

The UX115 device can be controlled directly using USB or indirectly using Ethernet.

This section discusses how to connect the UX115 device to a controlling device.

To connect to a controlling device through a USB

The UX300 host device installs the USB device driver automatically. The USB data is encrypted with authentication upon startup.

  1. Connect the USB Type B plug to the rear connector of the UX115 device.

  2. Connect the other end of the cable to a USB port on the controlling device.

Figure 4: Sample connection to a UX300 Controller through USB

To connect to a controlling device through LAN

  1. Connect the LAN port plug to the rear connector of the UX115 device and the other end to the network.

  2. Connect the other end of the cable to a LAN port on the controlling device and the other end to the network.

Figure 5: Sample connection to a UX300 Controller through LAN

Connecting Power Supply

Verifone can provide a power supply for the UX115 device if required.

For more details on the usage of the power supply, contact Verifone representative. See Accessories and Documentation.

Attach and route all cables between the UX115 device and all peripheral units before connecting to the power source.

To protect against possible damage caused by lightning strikes and electrical surges, Verifone recommends installing a power surge protector.

Power Connection

The UX115 device connects to external power using a power pack (PWR159-00X01-A).

Connect the power cable to the power port on the UX115 device and the other end to your power source.

Figure 6: Connecting Power Supply to the UX115

For more details on the usage of the power supply, contact Verifone representative. For cable ordering information, see Accessories and Documentation.

Grounding UX115 Device

When the UX115 device is connected to the UX300/UX301/UX410 controller, it is important to ground the units.

For cable ordering information, see Accessories and Documentation.

  1. Remove a mounting nut, exposing a stud from the back of the UX115 device (do not remove the cable retainer nut). See Figure 7 (A).

  2. Attach the grounding cable (VPN WIR159-302-01-A) from the UX115 Device to the UX300 and the grounding cable (VPN WIR159-302-02-A) from the UX115 device to a ground installation. See Figure 7 (B).

Figure 7: Grounding UX115 device and UX300 Units
  1. Tighten the nut to secure the UX115 device.

Tighten the nuts with a recommended torque of 5.0 kgf cm (0.49 Nm or 4.3 lbf in).

  1. Remove a mounting nut, exposing a stud from the back of the UX300 unit.

  2. On the UX300 unit stud, attach the other end of the grounding cable (VPN WIR159-302-01-A) from the UX115 and the second grounding cable (VPN WIR159-302-02-A, provided as a UX300 accessory) to a ground installation. See Figure 7 (B).

  3. Tighten the nut to secure the UX300 device.

    Tighten the nuts with a recommended torque of 5.0 kgfcm (0.49 Nm or 4.3 lbf in).

  4. Connect the other end of both ground cables to the nearest ground installations, to complete the grounding of the UX115 and UX300. See Figure 7 (C).

Last updated

Was this helpful?