Specifications
This chapter discusses power requirements, dimensions, and other specifications of the UX300-series card reader.
UX300 Models
The following table shows the various models and specifications of UX300-series units.
UX300-Standard
M159-300-000-WWA M159-300-000-WWA-B M159-300-100-WWA-B
UX300-Standard, Mag/Chip Reader and controller interface: 12 V in, LAN, RS232, USB-Slave, USB-Master, NFC-Antenna.
UX300-MDB
M159-300-010-WWA-B
UX300-MDB; UX300-Standard plus following interface: MDB, 4xUSB-Master, 2xRS232 Powered.
UX300-PSTN
M159-300-020-WWA-B
UX300-PSTN; UX300-Standard plus following interface: MDB, 4xUSB-Master, 1xRS232 Powered, PSN.
UX300-ISDN
M159-300-030-WWA-B
UX300-ISDN; UX300-Standard plus following interface: MDB, 4xUSB-Master, 1xRS232 Powered, ISDN.
UX300-GPRS
M159-300-040-WWA-B
UX300-GPRS; UX300-Standard plus following interface: MDB, 4xUSB-Master, 1xRS232 Powered, GPRS.
UX300-Petrol
M159-300-050-WWA-B
UX300-Petrol; UX300-Standard plus following interface: 24V, 4xUSB-Master, 2xRS232 Powered, RS485.
UX300-LAN
M159-300-060-WWA-B
UX300-LAN; UX300-Standard plus following interface: MDB, 4xUSB-Master, 2xRS232 Powered, 2nd LAN.
UX300-WPWR
M159-300-070-WWA-C
UX300-WPWR; UX300-Standard plus following Interface; 9 to 43 V Power In; PCI 3.1 and UKCC compliant.
Unit Power Requirements
UX300-Standard
Operation voltage: 9 V DC to 12 V DC
Idle Power: 2 W
Typical Power: 3 W (CTLS read), 4W (UX100 display heater), 0.5W (UX100/110), 5W (RS232-vout)
Sleep Mode: Approximately 30 to 50 mW, wakeup time 7 sec.
UX300-MDB, UX300-PSTN, UX300-ISDN, UX300-GPRS, UX300-LAN, UX300-WPWR
Operation voltage: 9 V DC to 43 V DC
Idle Power: 4 W
Typical Power: 3 W (CTLS read), 4 W (UX100 display heater), 0.5 W (UX100/110), 5 W (RS232-vout),
10W(USB-Master), 3 W (GPRS connect)
Sleep Mode: Approximately 30 to 50 mW, wakeup time 7 sec.
UX300-Petrol
Operation voltage: 24 V DC
Idle Power: 4 W
Typical Power: 3 W (CTLS read), 4 W (UX100 display heater), 0.5 W (UX100/110), 5 W (RS232-vout),
10W(USB-Master), 70 W (printer)
Sleep Mode: Approximately 30 to 50 mW, wakeup time 7 sec.
Temperature
Operating temperature:
-20°C to 70°C (-4°F to 158°F) Standard unit
-20°C to 65°C (-4°F to 149°F) MDB, LAN, Petrol units
0°C to 65°C (32°F to 149°F) PSTN, ISDN units
Storage temperature: -25°C to 70°C (-13°F to 158°F)
Power Supply rated for indoor use only: 12 V DC 3.3A, operating temperature 0°C to 40°C (32°F to 104°F)
Power Supply rated for outdoor use: 24 V, DC 3.75 A up to 40°C (DC 2.5 A up to 60°C), operating temperature -25°C to 60°C
Relative humidity: 5% to 90% RH non-condensing
External Dimensions
Height: 72 mm (2.83 in)
Width: 96 mm (3.78 in)
Depth: 150 mm (5.9 in)
Weight
Unit weight: 750 g (26.46 oz)
Memory
128 MB DDRAM
256 MB NAND-Flash
Magnetic Stripe Card
Triple-track
Smart Card Reader
Non-sliding
Card conserving plated landing contacts
SAM Requirements
2 SAM slots
Peripheral Ports
Consistent ports:
Power
Powered USB Type A for UX PIN pads (host)
USB Type B (client)
COM1 (powered)
ETH (LAN) connection with 2 colored LEDs for link state and speed indication
Analog RF CTLS antenna connector to the UX400 CTLS unit
8-PIN to RJ45 connector to UX400 CTLS antenna unit
Model-dependent cable connection board:
4 Powered USB Type A
MDB
Additional COM powered ports
GPRS antenna
ISDN
PSTN
RS-485
An additional ETH connection with 2 colored LEDs for link state and speed indication
Printer COM
Communication
COM: Up to 115200 bps, HW RTS/CTS handshake
MDB: 9600 bps fix, 9E1
RS-485: Up to 115200 bps, half duplex
Display
3 status LEDs on the front (payment application controlled)
Last updated