This chapter describes the setup procedure for the UX400 contactless reader, in the following sections:
Selecting Reader Location
Use the following guidelines when selecting a location for your reader:
Select a location convenient for the customer.
Select a location near the controlling device for the contactless unit.
For safety, do not string cables or cords across a walkway.
Avoid placing metallic objects at the front and around the card reader.
Environmental Factors
The front panel of the device is dustproof and fade-proof. The UX400 is also water-resistant, according to IP65 ratings.
Unpacking the Shipping Carton
Open the shipping carton and carefully inspect its contents for possible tampering or shipping damage.
Remove the items from the shipping carton. The standard package contains:
The UX400 contactless reader.
One SMA (RF) coaxial cable.
One RJ-45 communication cable for connecting with the UX300 card reader.
Refer to Accessories and Documentation for more information about related accessories.
Remove any protective plastic over the front display before use, or the unit may not work properly.
Remove any protective wrap before mounting the unit.
Save the shipping carton and packing material for future repacking or moving of the device.
Do not use a unit that has been damaged.
If a label or component appears damaged, please notify the shipping company and your Verifone service provider immediately.
Examining the CTLS Reader Features
Before you continue the installation process, notice the features of the reader.

Front Functions
The front of the contactless device shows the following:
Customer-view indicator LEDs
The CTLS logo
Mounting stud holes

Back Functions
The rear of the contactless device shows the following connectors:
RJ-45 host communication connector
SMA (RF) antenna connector
Connecting Unit to a Controlling Device
Use the following cables to connect the UX400 to the UX300 controlling device:
RJ-45 8-pin cable (VPN CBL159-301-01-A)
SMA cable (VPN CBL159-302-02-A)
Both connections are necessary for using the UX400 contactless unit.
Connect the RJ-45 plug to the rear of the UX400.

Connect the 8-pin connector to the UX400.
Screw in the SMA connector to the ports of the UX400 and UX300.
Contactless Support
This device supports the global contactless program specifications from American Express, MasterCard, Visa, Discover, ISIS SmartTap, and Google Wallet with virtually no changes to existing payment hardware or software.
Mounting the Reader
The UX400 is designed to be flush-mounted to the mounting surface, without further need for any external mounting devices.
Ensure that your mounting frame has a thickness of 2 mm.
To mount the UX400:
Peel off the plastic liner from the front of the unit.

Align the unit's stud holes with the stud holes of your mounting surface.
Flush-mount the reader and secure the unit with M5 nuts.
Avoid placing metallic objects at the front and around the card reader.
Using the Reader
The contactless reader is only active when signaled by an application for the start of a contactless card transaction.
When active, the UX400's contactless logo lights up.
Conducting a Contactless Transaction
To conduct a contactless transaction, hold the card (within 4 cm) or gently tap against the surface of the contactless antenna, marked by the logo.

The contactless unit uses various audible and visual confirmations to confirm transactions.
Last updated