For the complete documentation index, see llms.txt. This page is also available as Markdown.

Fuel Hardware Peripherals Supported

Verifone requires use of at least the “Minimum Version” below. Customers must consult with the Dispenser manufacturer to determine optimal version as they may recommend or require a higher version.

Dispensers Supported

Gilbarco Dispensers

Gilbarco Pre-modular dispensers must be on a separate board and as such are not supported with Verifone RubyCi, as there is only one connection out for fuel.

Dispenser
Description
Minimum Version

Encore 700

Pump Control Node

2.9.42

Encore 500

Pump Control Node

1.8.30

Encore 300

Digital Valve

20.1.10

Encore 300

Digital Valve with Enhanced Security

20.2.24

Encore 300

Proportional Valve

10.1.10

Encore 300

Proportional Valve with Enhanced Security

10.2.23

MPD

Legacy

70.9.92

MPD

Modular Advantage

70.9.92

MPD-3

LCDs

54.3.10

MPD-3

SIDs

53.7

Selectable Blender

Modular Advantage

75.6.10

Wayne Dispensers

For Model V490D1/U (Vista 1V), the version must be 47.

The dispenser must be programmed as one of the following types: Type 1, 2, 30 or 40. Verifone Commander will not support the dispenser programmed as any other type, including Types 3 through 29.

Dispenser
Description
Minimum

Ovation

iGem

85

iX

iGem

85

Vista 3V

iGem

49

Vista 2V

Dispenser

14

Vista 1V (See first note below)

Dispenser

49

Vista

Dispenser

See note above

SC-82

Dispenser

See note above

Dispenser Interfaces

The Verifone Commander Forecourt Interface Box communicates directly with Wayne, Tokheim, and Gilbarco dispensers.

Dispenser/ Interface

Supported: Yes/No

Minimum Version

Notation

Bennett

DOSPIB

No

515

Yes

v6.20

Horizon 1

Yes

v6.27

Supports PPU Discounting with Bennett 515 interface box, firmware v.507

Horizon 2

Yes

v2.15

Supports PPU Discounting with Bennett 515 interface box, firmware v.507

Pacific

Yes

v2.11

Supports Bennett SPM with Bennett 515 interface box with version v.6.20 Supports PPU Discounting

Tokheim

DHC

Yes

v6.17

Supports PPU Discounting

VXDHC

Yes

v4200.03.09

Supports PPU Discounting

Dresser/Wayne

CPU

No

Uses the Verifone Commander Forecourt Interface

PIB

No

Uses the Verifone Commander Forecourt Interface

Fusion

No

Uses the Verifone Commander Forecourt Interface

HyperPIB

No

Uses the Verifone Commander Forecourt Interface

Arbitration Board

No

Uses the Verifone Commander Forecourt Interface

Gilbarco

Legacy PAM 1000

No

Uses the Verifone Commander Forecourt Interface

PAM 1000

No

Uses the Verifone Commander Forecourt Interface

PAM 5000

No

Uses the Verifone Commander Forecourt Interface

SMART Connect

No

Uses the Verifone Commander Forecourt Interface